Product Information
Aug 2010
Terluran® GP-35  

 

Product Description
Terluran GP-35 is a very high flow grade of ABS for injection molding with good resistance to impact and heat deflection.

RHEOLOGICAL ISO Test Method Property Value
Melt Volume Rate (220 °C/10 Kg), cc/10min. 1133 34
PHYSICAL ISO Test Method Property Value
Density, g/cm³ 1183 1.04
MECHANICAL ISO Test Method Property Value
Tensile Modulus, MPa 527  
    23°C 2,300
Tensile stress at yield, MPa 527  
    -40°C 63
    23°C 44
    80°C 19
Tensile strain at yield, % 527  
    23°C 2.4
Nominal strain at break, % 527  
    23°C 12
Flexural Strength, MPa 178  
    23°C 65
IMPACT ISO Test Method Property Value
Izod Impact, kJ/m² 180  
    23°C 22
Charpy Notched, kJ/m² 179  
    23°C 19
    -30°C 7
Charpy Unnotched, kJ/m² 179  
    23°C 125
    -30°C 90
THERMAL ISO Test Method Property Value
HDT A (1.8 MPa), ° C 75 94
HDT B (0.45 MPa), ° C 75 99
Coef. of Linear Thermal Expansion, Parallel, mm/mm °C 0.95 X10-4
Vicat Softening Temperature VST/B/50 °C 306 95
ELECTRICAL ISO Test Method Property Value
Volume Resistivity IEC 60093 >1E13
Electric Strength, Short Time, 1.5 mm IEC 60243-1 38
UL RATINGS UL Test Method Property Value
Flammability Rating, 1.5mm UL94 HB
Relative Temperature Index, 1.5mm UL746B  
    Mechanical w/o Impact, °C 90
    Mechanical w/ Impact, °C 80
    Electrical, °C 90

Note
Although all statements and information in this publication are believed to be accurate and reliable, they are presented gratis and for guidance only, and risks and liability for results obtained by use of the products or application of the suggestions described are assumed by the user. NO WARRANTIES OF ANY KIND, EITHER EXPRESS OR IMPLIED, INCLUDING WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE, ARE MADE REGARDING PRODUCTS DESCRIBED OR DESIGNS, DATA OR INFORMATION SET FORTH. Statements or suggestions concerning possible use of the products are made without representation or warranty that any such use is free of patent infringement and are not recommendations to infringe any patent. The user should not assume that toxicity data and safety measures are indicated or that other measures may not be required.

 

  BASF Corporation
Styrenics
100 Campus Drive
Florham Park, New Jersey 07932
General Information: InfoPoint: 1-800-238-4075
eMail: basf_infopoint@basf.com